Ysav01b2 Medical Instrument Anesthesia Machine System

Product Name: Anesthesia Machine
MOQ: 1 Set
Feature: Anesthetic Equipment

Product Description

📋 Basic Specifications
Model NO.YSAV01B2
Display5.4'' Display Screen
AdvantageDurable
Flowmeters4-Tube Flowmeters
Respiration ModeA/C, IPPV, SIPPV, IMV, SIMV, Manual
Respiratory Rate1~99bpm
PackageStandard Carton
Oxygen Flush25~75 L/Min
🏥 Product Overview
YSAV01B2 Medical Instrument Anesthesia Machine System
Anesthesia Machine View 1
Anesthesia Machine View 2
🛠 Physical Specifications
  • Screen: 5.4'' High-definition Display
  • Application: Suitable for Adult & Child
  • System: Pneumatically powered & electrically controlled
  • Working Modes: Closed, Semi-Closed, Semi-Open
  • Flow Control: 4-Tube Flowmeters (O2: 0.1~10L/Min, N2O: 0.1~10L/Min)
  • Mobility: 4 anti-static rubber castors (2 lockable)
  • Storage: Two totally extractable drawer units
⚙️ Technical Specifications
💨
Gas Requirements: Medical Oxygen (O2) and Nitrous Oxide (N2O) with pressure 0.32~0.6MPa.
📊
Ventilation Performance: Tidal Volume range 0~1500ML; Respiratory Rate 1~99bpm; I/E Ratio 4:1 ~ 1:10 with inverse ratio ventilation.
🛡️
Safety Features: Safety valve <12.5 kPa; O2 concentration in mixed gas >21%; Emergency Oxygen Flush 25~75 L/min.
Technical Details 1
Technical Details 2
🔔 Intelligent Alarm System
  • Airway Pressure: Audible & visual alarms (Upper: 0.3~6.0 kPa)
  • Tidal Volume: Upper alarm 50~2000ml, Lower 0~1800ml
  • Power Supply: Immediate alarm upon AC/DC power failure
  • Alarm Duration: Sustains for more than 120 seconds
Frequently Asked Questions
Q1: Which patients is the YSAV01B2 suitable for?
The YSAV01B2 anesthesia machine is designed to be versatile and is suitable for both adult and pediatric (child) patients.
Q2: What are the available ventilation modes?
It supports multiple modes including A/C, IPPV, SIPPV, IMV, SIMV, and Manual mode to accommodate various clinical requirements.
Q3: How does the flowmeter system work?
The system utilizes a 4-tube flowmeter for precise control of Oxygen (O2) and Nitrous Oxide (N2O), both ranging from 0.1 to 10L/Min.
Q4: What safety mechanisms are integrated regarding oxygen concentration?
The machine ensures that the oxygen concentration in the mixed gas (N2O/O2) is always greater than 21% for patient safety.
Q5: Is the unit easy to move within a hospital setting?
Yes, it is fitted with four anti-static rubber castors. Two of these are equipped with foot-operated brakes for easy maneuverability and stable positioning.
Q6: What happens in case of a power failure?
The machine features a Power Supply Alarm that triggers immediately if AC/DC power fails, with an alarm duration of over 120 seconds.